Accent Lighting
Directional lighting to emphasize a particular object or to draw attention to a part of the field of view.
Absorption
The dissipation of light within a surface or medium.
Accommodation
The process by which the eye changes focus from one distance to another.
Adaptation
The process by which the visual system becomes accustomed to more or less light than it was exposed to during an immediately preceding period. It results in a change in the sensitivity of the eye to light.
Alternating Current (AC)
Flow of electricity which cycles or alternates direction many times per second. The number of cycles per second is referred to as frequency. Most common frequency used in this country is 60 Hertz (cycles per second).
Ambient Lighting
Background or fill light in a space.
Amperes (amps or A)
The unit of measurement of electric current.
Back Lighting
The illumination provided for scenery in off-stage areas visible to the audience.
Baffle
An opaque or translucent element that serves to shield a light source from direct view at certain angles, or serves to absorb unwanted light.
Ballast
An auxiliary device consisting of induction windings wound around a metal core and sometimes includes a capacitor for power correction. It is used with fluorescent and HID lamps to provide the necessary starting voltage and to limit the current during operation.
“Batwing” Distribution
Candlepower and distribution which serves to reduce glare and veiling reflections by having its maximum output in the 30° to 60° zone.
Candela
The unit of measurement of luminous intensity of a light source in a given direction.
Candlepower
Luminous intensity expressed in candelas.
Candlepower Distribution
Curve A curve, generally polar, representing the variation of luminous intensity of a lamp or luminaire in a plane through the light center.
Cavity Ratio
A number indicating cavity proportions calculated from length, width and height.
Class “P” Ballast
Contains a thermal protective device which deactivates the ballast when the case reaches a certain critical temperature. The device resets automatically when the case temperature drops to a lower temperature.
Coefficient of Utilization (CU)
The ratio of the luminous flux (lumens) from a luminaire calculated as received on the work-plane to the luminous flux emitted by the luminaires lamps alone.
Cold Cathode Lamp
An electric-discharge lamp whose mode of operation is that of a flow discharge.
Colorimetry
The measurement of color.
Color Rendering Index (CRI)
Measure of the degree of color shift objects undergo when illuminated by the light source as compared with the color of those same objects when illuminated by a reference source of comparable color temperature.
Color Temperature
The absolute temperature of a blackbody radiator having a chromaticity equal to that of the light source.
Cone Reflector
Parabolic reflector that directs light downward thereby eliminating brightness at high angles.
Contrast
The difference in brightness (luminance) of an object and its background.
Cool Beam Lamps
Incandescent PAR lamps that use a special coating (dichroic interference filter) on the reflectorized potion of the bulb to allow heat to pass out the back while reflecting only visible energy to the task, thereby providing a “cool beam” of light.
Cove Lighting
Lighting comprising sources sheilded by a ledge or horizontal recess, and distributing light over the ceiling and upper wall.
Cutoff Luminaires
Outdoor luminaires that restrict all light output to below 85° from vertical.
Digital Addressable Lighting Interface (DALI)
An open communications protocol used by multiple control and ballast manufacturers for digital control.
Dimming Ballast
Special fluorescent lamp ballast, which when used with a dimmer control, permits varying light output.
Direct Current (DC)
Flow of electricity continuously in one direction from positive to negative.
Direct Lighting
Lighting involving luminaires that distribute 90 to 100% of emmited light in the general direction of the surface to be illuminated. The term usually refers to light emitted in a downward direction.
Direct Glare
Glare resulting from high luminances or insufficiently shielded light sources in the field of view. It usually is associated with bright areas, such as luminaires, ceilings and windows which are outside the visual tasks or region being viewed.
Discharge Lamp
A lamp in which light (or radiant energy near the visible spectrum) is produced by the passage of an electric current through a vapor or a gas.
Discomfort Glare
Glare producing discomfort. It does not necessarily interfere with visual performance or visibility.
Emergency Lighting
Lighting system designed to provide minimum illumination required for safety, during power failures.
Efficacy
See Lamp Efficacy.
Efficiency
See Luminaire Efficiency.
Equivalent Sphere Illumination (ESI)
The level of sphere illumination which would produce task visibility equivalent to that produced by a specific lighting environment.
“ER” (Elliptical Reflector)
Lamp whose reflector focuses the light about 2? ahead of the bulb, reducing light loss when used in deep baffle downlights.
Extended Life Lamps
Incandescent lamps that have an average rated life of 2500 or more hours and reduced light output compared to standard general service lamps of the same wattage.
Fill Light
Illumination added to reduce shadows or contrast range.
Floodlighting
A system designed for lighting a scene or object to a luminance greater than its surroundings. It may be for utility, advertising or decorative purposes.
Fluorescent Lamp
A low-pressure mercury electric-discharge lamp in which a phosphor coating transforms some of the ultraviolet energy generated by the discharge into light.
Footcandle (fc)
The unit of illuminance when the foot is taken as the unit of length. It is the illuminance on a surface one square foot in area on which there is a uniformly distributed flux of one lumen.
Foot Lambert (fl)
A unit of luminance of perfectly diffusing surface emitting or reflecting light at the rate of one lumen per square foot.
Footlights
A set of striplights at the front edge of the stage plateform used to soften face shadows cast by overhead luminaires and to add general toning lighting from below.
General Lighting
See Ambient Lighting.
General Service Lamps
“A” or “PS” incandescent lamps.
Glare
The sensation produced by luminance within the visual field that is sufficiently greater than the luminance to which the eyes are adapted to cause annoyance, discomfort, or loss in visual performance and visibility.
Ground Relamping
Relamping of a group of luminaires at one time or reduce relamping labor costs.
High Intensity Discharge (HID) Lamp
A discharge lamp in which the light producing arc is stabilized by wall temperature, and the arc tube has a bulb wall loading in excess of three watts per square centimeter. HID lamps include groups of lamps known as mercury, metal halide, and high pressure sodium.
High Output Fluorescent Lamp
Operates at 800 or more milliamperes for higher light output than standard fluorescent lamp (430MA).
High Pressure Sodium (HPS) Lamp
High intensity discharge (HID) lamp in which light is produced by radiation from sodium vapor. Includes clear and diffuse-coated lamps.
Incandescence
The self-emission of radiant energy in the visible spectrum due to the thermal excitation of atoms or molecules.
Incandescent Lamp
A lamp in which light is produced by a filament heated to incandescence by an electric current.
Instant Start Fluorescent Lamp
A fluorescent lamp designed for starting by a high voltage without preheating of the electrodes.
Inverse Square Law
The law stating that the illuminance at a point on a surface varies directly with the intensity of a point source, and inversely as the square of the distance between the source and the point. If the surface at the point is normal to the direction of the incident light, the law is expressed by fc=cp/d2.
Kelvin
Unit of measurement for color temperature. The Kelvin scale starts from absolute zero, which is -273° Celsius.
Kilowatt-Hour (KWH)
Unit of electrical power consumed over a period of time. KWH = watts/1000 x hours used.
Lamp
An artificial source of light (also portable luminaire equipped with a cord and plug).
Lamp Efficacy
The ratio of lumens produced by a lamp to the watts consumed. Expressed as lumens per watt (LPW).
Lamp Lumen Depreciation (LLD)
Multiplier factor in illumination calculations for reduction in the light output of a lamp over a period of time.
Light
Radiant energy that is capable of exciting the retina and producing a visual sensation. The visible portion of the electromagnetic spectrum extends from about 380 to 770 nm.
Lens
Used in luminaires to redirect light into useful zones.
Local Lighting
Lighting designed to provide illuminance over a relatively small area or confined space without providing any significant general surrounding lighting.
Louver
A series of baffles used to shield a source from view at certain angles or to absorb unwanted light. The baffles usually are arranged in a geometric pattern.
Long Life Lamps
See Extended Life Lamps.
Low Pressure Sodium Lamp
A discharge lamp in which light is produced by radiation of sodium vapor at low pressure producing a single wavelength of visible energy, i.e. yellow.
Low Voltage Lamps
Incandescent lamps that operate at 6 to 12 volts.
Lumen
The unit of luminous flux. It is the luminous flux emitted within a unit solid angle (one steradian) by a point source having a uniform luminous intensity of one candela.
Luminaire
A complete lighting unit consisting of a lamp or lamps together with the parts designed to distribute the light, to position and protect the lamps and to connect the lamps to the power supply.
Luminaire Direct Depreciation (LDD)
The multiplier to be used in illuminance provided by clean, new luminaires to the reduced illuminance that they will provide due to direct collection on the luminaires at the time at which it is anticipated that cleaning procedures will be instituted.
Luminaire Efficiency
The ratio of luminous flux (lumens) emitted by a luminaire to that emitted by the lamp or lamps used.
Luminance
The amount of light reflected or transmitted by an object.
Lux
The metric unit of illuminance. One lux is one lumen per square meter (lm/m2).
Maintenance Factor (MF)
A factor used in calculating illuminance after a given period of time and under given conditions. It takes into account temperature and voltage variations, dirt accumulation on luminaire and room surfaces, lamp depreciation, maintenance procedures and atmosphere conditions.
Mercury Lamp
A high intensity discharge (HID) lamp in which the major portion of the light is produced by radiation from mercury. Includes, clear, phosphor-coated and self-ballasted lamps.
Metal Halide Lamp
A high intensity discharge (HID) lamp in which the major portion of the light is produced by radiation of metal halides and their products of dissociation-possible in combination with metallic vapors such as mercury. Includes clear and phosphor coated lamps.
Nadir
Vertically downward directly below the luminaire or lamp; designated as 0°.
Overall Length (OAL)
Maximum overall length of a light fixture.
“PAR” Lamps
Parabolic aluminized reflector lamps which offer excellent beam control, come in a variety of beam patterns from very narrow spot to wide flood and can be used outdoors unprotected because they are made of “hard” glass that can withstand adverse weather.
Parabolic Louvers
A grid of baffles which redirect light downward and provide very low luminaire brightness.
Photometry
The measurement of light quantities.
Point Method Lighting Calculation
A lighting design procedure for predetermining the illuminance at various locations in lighting installations, by use of luminaire photometric data.
Polarization
The process by which the transverse vibrations of light waves are oriented in a specific plane. Polarization may be obtained by using either transmitting or reflecting media.
Power Factor Ratio of: Watts (volts x amperes)
Power factor in lighting is primarily applicable to ballasts. Since volts and watts are usually fixed, amperes (or current) will go up as power factor goes down. This necessitates the use of larger wire sizes to carry the increased amount of current needed with Lowe Power Factor (L.P.F) ballasts. The addition of a capacitor to an L.P.F. ballast converts it to a H.P.F. ballast.
Preheat Fluorescent Lamp
A fluorescent lamp designed for operation in a circuit requiring a manual or automatic starting switch to preheat the electrode in order to start the arc.
“R” Lamps
Reflectorized lamps available in spot (clear face) and flood (frosted face).
Rapid Start Fluorescent Lamp
A fluorescent lamp designed for operation with a ballast that provides a low-voltage winding for preheating the electrodes and initiating the arc without a starting switch or the application of high voltage.
Raw Footcandles
See Footcandles.
Reflection
Light bouncing off a surface. In specular reflection the light strikes and leaves a surface at the same angle. Diffuse reflected light leaves a surface in all directions.
Reflectance
Sometimes called reflectance factor. The ratio of reflected light to incident light (light falling on a surface). Reflectance is generally expressed in percent.
Reflected Glare
Glare resulting from specular reflections of high luminances in polished or glossy surfaces in the field of view. It usually is associated with reflections from within a visual task or areas in close proximity to the region being viewed.
Reflector
A device used to redirect the light flow from a source by bouncing it off the surface.
Refraction
The process by which the direction of a ray of light changes as it passes obliquely from one medium to another in which its speed is different.
Room Cavity Ration (RCR)
A number indicating room cavity proportions calculated from length, width and height.
Rough Service Lamps
Incandescent lamps designed with extra filament supports to withstand bumps, shocks and vibrations with some loss in lumen output.
Self-ballasted Mercury Lamps
Any mercury lamp of which the current-limiting device is an integral part.
Silver Bowl Lamps
Incandescent “A” lamps with a silver finish inside the bowl or portion of the bulb. Used for indirect lighting.
Spacing Ratio
Ratio of the distance between luminaire centers to the mounting height above the work-plane for uniform illumination.
Spectral Energy Distribution (SED)
Curves A plot of the level of energy at each wavelength of a light source.
Sphere Illumination
The illumination on a task from a source providing equal luminance in all directions about that task, such as an illuminated sphere with the task located at the center.
Surface Mounted Luminaire
A luminaire that is mounted directly on a ceiling.
Suspended (Pendant) Luminaire
A luminaire that is hung from a ceiling by supports.
Task Lighting
Lighting directed to a specific surface or area that provides illumination for visual tasks.
Three-Way Lamps
Incandescent lamps that have two separately switched filaments permitting a choice of three levels or light such as 30/70/100, 50/100/150 or 100/200/300 watts. They can only be used in a base down position.
Transformer
A device to raise or lower electric voltage.
Transmission
The passage of light through a material.
Tungsten-Halogen Lamp
A gas filled tungsten incandescent lamp containing a certain proportion of halogens.
Veiling Reflections
Regular reflections superimposed upon diffuse reflections from an object that partially or totally obscure the details to be seen by reducing the contrast. This is sometimes called reflected glare.
Vibration Service Lamps
See Rough Service Lamps.
Visual Comfort Probability (VCP)
The rating of a lighting system expressed as a percent of people who, when viewing from the specified location and in a specified direction, will be expected to find it acceptable in terms of discomfort glare.
Visual Edge
The line on a isolux chart which has a value equal to 10% of the maximum illumination.
Visual Field
The field of view that can be perceived when the head and eyes are kept fixed.
Wall Wash Lighting
A smooth even distribution of light over a wall.
Zonal Cavity Method Lighting Calculation
A lighting design procedure used for predetermining the relation between the number and types of lamps or luminaires, the room characteristics, and the average illuminance on the work-plane. It takes into account both direct and reflected flux.